Advanced Aberration Analysis Suite

Advanced Aberration Analysis Suite

Efficiently evaluate optical aberrations across complete optical systems


Understanding optical aberrations across all system configurations, wavelengths, and field points is essential for achieving high image quality and optical performance.


Advanced Aberration Analysis Suite streamlines this evaluation by systematically calculating spherical aberration, coma, astigmatism, field curvature and chromatic aberrations - providing clear insights for both design validation and system improvement.


Key Features:


- Comprehensive Analysis: Calculates all optical aberrations for each configuration, wavelength, and field point of the optical system.


- High Precision Output: Optical aberrations are expressed in milliwaves (mλ) for accurate and meaningful interpretation.


- Graphical Visualization: Intuitive plots reveal spherical aberration trends and system characteristics.


- Data Export: All calculated values are saved into structured text files for further analysis and documentation.


- Seamless Workflow Integration: Results are also summarized directly in the MATLAB command window for quick inspection.


With Advanced Aberration Analysis Suite, optical engineers and designers can explore spherical aberration in greater detail, enabling better-informed design choices and enhanced optical system performance.


Order Advanced Aberration Analysis Suite with one-month free trial


Details of Advanced Aberration Analysis Suite

Features Standard Version

Connection Mode

Standalone extension

Interactive extension

Simulations

Zernike spherical aberration

Zernike coma

Zernike astigmatism

Seidel spherical aberration

Seidel coma

Seidel astigmatism

Field curvature

Distortion

Chromatic aberrations


Users can enable or disable each simulation type individually, allowing full customization of the analysis process.

Output figures

Zernike Astigmatism vs. Wavelength Across Field Points

Zernike Astigmatism vs. Field Across Wavelengths

Maximum Zernike Astigmatism vs. Configuration

Zernike Astigmatism vs. Field Across Wavelengths

Zernike Astigmatism vs. Wavelength Across Field Points

Zernike Astigmatism vs. Configuration Across Wavelengths

Zernike Astigmatism vs. Configuration Across Fields

Maximum Seidel Astigmatism vs. Configuration

Seidel Astigmatism vs. Wavelength

Seidel Astigmatism vs. Wavelength Across Configurations

Seidel Astigmatism vs. Surface Number Across Wavelengths

Seidel Astigmatism vs. Wavelength Across Surfaces

Seidel Astigmatism vs. Configuration Across Wavelengths

Seidel Astigmatism vs. Wavelength Across Configurations

Output figure formats

MATLAB files (".fig", ".m", ".mfig"), JPEG, PNG, TIFF*, Enhanced metafile**, BMP***, HDF, PBM****, PCX*****, PGM****, PPM****


Users can enable or disable each output format individually, allowing full customization of the export process.

Version

11.55.01

Availibility

Immediate

License Model

Annual Lease (Linked to Zemax Serial Number)

Support

Included During Lease Term

Updates

Included During Lease Term

Support for installation

Support: 24/7, 365 days a year

Compatible versions

All Zemax OpticStudio versions

All Ansys Zemax OpticStudio versions

Price

$3,950 / €3,600 + VAT per year

Discounts

5% Off for Each Additional License (Up to 50%)

Payment Terms

Net 30 Days

Payment Methods

Bank Transfer (German or US Account)

Legend

*: compressed & not compressed

**: Windows only

***: Monochrome, 16m, 8-bit

****: plain format & raw format

*****: 1-bit, 24-bit color (three 8-bit planes), 8-bit newer color (256 color), older color (EGA/VGA 16-color)

Details of Advanced Coma Analysis

Features Standard Version

Connection Mode

Standalone extension


Interactive extension

Simulations

Zernike spherical aberration

Zernike coma

Zernike astigmatism

Seidel spherical aberration

Seidel coma

Seidel astigmatism

Field curvature

Distortion

Chromatic aberrations


Users can enable or disable each simulation type individually, allowing full customization of the analysis process.

Output figures

Zernike Astigmatism vs. Wavelength Across Field Points


Zernike Astigmatism vs. Field Across Wavelengths


Maximum Zernike Astigmatism vs. Configuration


Zernike Astigmatism vs. Field Across Wavelengths


Zernike Astigmatism vs. Wavelength Across Field Points


Zernike Astigmatism vs. Configuration Across Wavelengths


Zernike Astigmatism vs. Configuration Across Fields


Maximum Seidel Astigmatism vs. Configuration


Seidel Astigmatism vs. Wavelength


Seidel Astigmatism vs. Wavelength Across Configurations


Seidel Astigmatism vs. Surface Number Across Wavelengths


Seidel Astigmatism vs. Wavelength Across Surfaces


Seidel Astigmatism vs. Configuration Across Wavelengths


Seidel Astigmatism vs. Wavelength Across Configurations

Output figure formats

MATLAB files (".fig", ".m", ".mfig"), JPEG, PNG, TIFF*, Enhanced metafile**, BMP***, HDF, PBM****, PCX*****, PGM****, PPM****


Users can enable or disable each output format individually, allowing full customization of the export process.

Version

11.55.01

Availibility

Immediate

License Model

Annual Lease (Linked to Zemax Serial Number)

Support

Included During Lease Term

Updates

Included During Lease Term

Support for installation

Support: 24/7, 365 days a year

Compatible versions

All Zemax OpticStudio versions

All Ansys Zemax OpticStudio versions

Price

$3,950 / €3,600 + VAT per year

Discounts

5% Off for Each Additional License (Up to 50%)

Payment Terms

Net 30 Days

Payment Methods

Bank Transfer (German or US Account)

Legend

*: compressed & not compressed

**: Windows only

***: Monochrome, 16m, 8-bit

****: plain format & raw format

*****: 1-bit, 24-bit color (three 8-bit planes), 8-bit newer color (256 color), older color (EGA/VGA 16-color)

Order Advanced Aberration Analysis Suite with One-Month Free Trial

Standard and Custom Extensions for Zemax OpticStudio and CODE V

AI-Driven Intelligent Optimization for Lens Design